Domoticz: Difference between revisions
No edit summary |
|||
Line 70: | Line 70: | ||
vi /etc/monit/monitrc | vi /etc/monit/monitrc | ||
(note - get rid of any leading spaces!) | |||
<pre> | <pre> | ||
with start delay 240 | with start delay 240 | ||
set mailserver mail.edgarbv.com | set mailserver mail.edgarbv.com port 587 | ||
set alert robin@edgarbv.com | set alert robin@edgarbv.com | ||
</pre> | </pre> | ||
Line 78: | Line 79: | ||
To check if mailing works, do | To check if mailing works, do | ||
<pre> | <pre> | ||
monit | service monit restart; tail -f /var/log/monit.log | ||
</pre> | </pre> | ||
Revision as of 14:45, 11 April 2019
Install
When installing there are two choices
- hand compile
- use curl (for the "easy" way)
Curl
Domoticz from binary comes with a static openssl1.0.0 dependency, which Debian no longer offers. So first
cd /usr/local/src wget http://security.debian.org/debian-security/pool/updates/main/o/openssl/libssl1.0.0_1.0.1t-1+deb8u11_amd64.deb dpkg -i libssl1.0.0_1.0.1t-1+deb8u11_amd64.deb apt-mark auto libssl1.0.0 apt install libpython3.5 libpython3.5-dev curl -sSL install.domoticz.com | bash cd /opt/domoticz/ ./updatebeta
(NB I install to /opt/domoticz)
Check if everything is running ok
journalctl -full -u domoticz.service
In the web interface go to Setup -> Log and check more
if links don't work, look here and choose the one with your architecture. Unstable only works on ARM
by hand
There is some flag about not using staticssl
when visiting the SSL site, you may need to remove the port number the installer gives you and just go to https://ip
fixing the system crashes
Sometimes when you visit your site, it will tell you the daemon is offline. Using /etc/init.d/domoticz.sh status you won't see much about why it's stopped:
/etc/init.d/domoticz.sh status ● domoticz.service - LSB: Home Automation System Loaded: loaded (/etc/init.d/domoticz.sh; generated; vendor preset: enabled) Active: active (exited) since Wed 2019-04-10 11:36:53 CEST; 21h ago Docs: man:systemd-sysv-generator(8) Apr 10 11:36:53 domoticz systemd[1]: Stopped LSB: Home Automation System. Apr 10 11:36:53 domoticz systemd[1]: Starting LSB: Home Automation System... Apr 10 11:36:53 domoticz domoticz.sh[19243]: 2019-04-10 11:36:53.511 Status…Cuz Apr 10 11:36:53 domoticz domoticz.sh[19243]: 2019-04-10 11:36:53.511 Status…:19 Apr 10 11:36:53 domoticz domoticz.sh[19243]: 2019-04-10 11:36:53.512 Status…cz/ Apr 10 11:36:53 domoticz domoticz.sh[19243]: domoticz: Domoticz is starting …... Apr 10 11:36:53 domoticz domoticz[19251]: Domoticz is starting up.... Apr 10 11:36:53 domoticz systemd[1]: Started LSB: Home Automation System. Apr 10 11:36:53 domoticz domoticz[19252]: Domoticz running... Apr 11 09:11:18 domoticz domoticz[19252]: Domoticz stopped...
You can restart it using /etc/init.d/domoticz.sh restart and in /var/log/messages you will see something like the following:
Apr 11 09:11:18 domoticz domoticz: Domoticz stopped... Apr 11 09:29:07 domoticz domoticz: Domoticz is starting up.... Apr 11 09:29:07 domoticz domoticz: Domoticz running...
In order to monitor the process you use monit, as described Monitoring domoticz
apt install monit vi /etc/monit/monitrc
(note - get rid of any leading spaces!)
with start delay 240 set mailserver mail.edgarbv.com port 587 set alert robin@edgarbv.com
To check if mailing works, do
service monit restart; tail -f /var/log/monit.log
and it should send you a status notification by mail.
Evohome
Go to Setup -> Hardware. Next to Type, select Evohome via Web API
Under username / pass, fill in your mytotalconnectcomfort.com credentials. Make sure Synchronise, show schedule and location are all on. You may either lower or raise the poll intervall to anything you like but if you set it to less than ten seconds it will automatically reset itself to 60 seconds.
After pressing the 'Add' button to add the hardware device, the rest of the configuration will occur automatically and you should see your Evohome heating zones (and Hot Water device if you have one) appear in the devices list after about ten seconds. If you like you can now disable 'Synchronize installation'.
You then go to Setup -> Devices.
Click on the green import button on the right of each device.
Changing the short graph
The temperature graphs only have day, month and year. You can change the day to 7 days for a more week like list:
[SETUP] -->>[SETTINGS] -->> [LOG HISTORY] -->> [SHORT LOG SENSORS] -->> choose between 1 - 7 days
Dashboard
To get the graphs on the dashboard you have to use an extension, Dashticz